X90 Series Point Level Monitor
Source
Holder/Radiation Source
The Ronan Point Level Systems use the cesium-137 isotope as the source of
radiation. The cesium isotope has been selected for its excellent penetration
capability and a thirty year half-live. The source activity is selected after
giving consideration to vessel and process parameters such as diameter and wall
thickness. This assures optimum response time, economy and safety while keeping
the source activity to a minimum.
The cesium-137 source material is encapsulated in a stainless steel capsule and
placed into the source holder. This ductile iron or steel housing is then lead
filled to provide shielding in all directions except where the radiation is
beamed to the detector. Licensed source holders provide a lockable shutter to
allow complete shielding during shipping, installation and maintenance.