ultra.gif (3846 bytes)   Oracle 160 Open Channel Flow Meter    
BS3680 Calculations
Open channel flow monitoring, with calculations in accordance with BS3680, including absolute and ratiometric calculations

Open Channel Flow Measurement Categories

Simple exponential
Selected primary element to BS3680
Others (Palmer Bowlus, H flume etc.)
A universal flow calculation
32 point curve fit linearisation
Velocity X Area input gives flow when no PMD is present by the addition of a 'Speedy' velocity sensor

Display

8 digit on board totaliser
6 digit display of flowrate or head
Resetable & a non resetable totaliser

Pump Control Features

Pump control on changing flow, level or rate of level to provide:

Fixed duty assist
Fixed duty backup
Alternate duty assist
Alternate duty backup
Duty backup and assist
Two pump sets
Service ratio duty assist
Service ratio duty backup
FOFO (alternate first on first off) duty assist

Alarm Functions

Alarm function on changing level to provide:

High or low level
In or out of band
Rate of filling or emptying
High or low temperature
System failed
Pump efficiency
 
The Pulsar Oracle 160 open channel flow meter provides non-contacting, maintenance-free accurate flow measurement and control, in a wide range of flumes and weirs by calculating flow from the measured head preceding a primary measurement device (PMD), using the time of flight, through air, ultrasound technique. Flow calculation is to the British Standard BS3680 where applicable.

The Oracle 160 uses advanced measurement and control routines, which include on board totalisation of flow and outputs for remote logging and alarm, will provide real advantages in the application. The standard choices of PMD factory installed give ease of calibration in comparison to other open channel flow units available.

Available as a 3 or 5 relay unit ensure maximum application choice and control versatility. Full flexible Pen-stock control is standard

The high level specification, which includes ac and DC supply capability in one unit, back lit LCD display, pump control software routines, two-way digital (RS232) communication and a choice of integral or optional remote programming, is all available in a choice of wall mount, fascia mount, panel mount or 19 inch rack mounting configurations.

An optional analogue input on the 5 relay version only allows the unit to accept input from Pulsars SPEEDY devices to provide, (for instance velocity) to enable an "area times velocity" Q=VA calculation to be utilised in situations where no PMD is present.


        

 

wpe1.jpg (4004 bytes)
Wall Mount

wpe4.jpg (2392 bytes)
Rack Mount

wpe3.jpg (2774 bytes)
Panel Mount

Fascia Mount

 

 

 