Mass Technologies, Inc.

P.O. Box 173187

Arlington, TX 76003-3187

 

600 series
Home Up

 

 

point.gif (5268 bytes)

Typical Industries

Chemical
Food and drink
Mineral extraction
Pharmaceutical
Power generation
Pulp and paper
Sewage and water treatment

Applications

Over spill alarm
Leak detection
Low level alarm
Pump protection

Features

Non-invasive point level detection
Relay version (600)
Two wire loop powered version (610)
Intrinsically safe version (611)
Microprocessor controlled
Auto calibrate 'wet' or 'dry'
Alarm 'wet' or 'dry'
Single button set up
Repeatability ± 1mm
Unique installation self-check routine.
  Series 600

Description

The Pulsarpoint 600 series is a range of ultrasonic non-invasive liquid and slurry level measurement switches. They provide easy to install reliable and non-intrusive point level indication. The Pulsarpoint 600 series is used on metal tanks containing liquids and slurries to provide indication of rising or falling liquid levels.

Application

The Pulsarpoint 600 is attached to the outer wall of a metal tank at a point coinciding with the level at which indication is required. Ultrasonic sound waves are transmitted through the side wall of the tank to detect the absence or presence of the liquid, by monitoring the characteristics of the reflected soundwaves. A change in condition is indicated once material reaches the required level. The output may be assigned to indicate a 'wet' or 'dry' condition at the required level.

Operation

The Pulsarpoint 600 series is non-intrusive by attaching the level measurement switch to the outside of a metal tank there is no need to drill or cut the tank wall and there is no contact with the fluid being measured. There are no moving parts and therefore no cleaning or maintenance requirements. This highly reliable non-invasive technology can be applied to many different fluids and once installed is easily calibrated. Among many typical applications the Pulsarpoint 600 will provide over-fill protection, leak detection or low level liquid alarm to prevent, for instance, pump damage.

Pulsarpoint 600 series operates within temperature ranges of -40 șC to +90 șC. The 600 version provides an output via a 1 amp volt free contact changeover. The 610 and 611 versions provide 4-20 mA point level indication. Simple to install using the mounting plate assembly provided with each unit, the 600 series can be used in existing process control applications without the need for modification. The 611 intrinsically safe version is available for use in flammable atmospheres.

A rugged stainless steel enclosure provides a high degree of protection from the bump, shock and vibrations within a typical industrial environment.

The Pulsarpoint 600 series incorporates a unique self-check routine which can be initiated from time to time and which will automatically self-check both system and installation integrity.

Calibration is via a single button with two LED status indicators. Calibration and set-up instructions are illustrated within the unit.

A liquid level repeatability of ± 1mm can be achieved through tank wall thickness of 2.5mm up to 40mm on metal tanks providing there is no internal or external corrosion present.


        

 

point600.jpg (76964 bytes)
Pulsarpoint 600

point600_4.jpg (73754 bytes)
Installation on a tank

 

 

 

Home ] Up ]