Process:
For 4-20mA, 0-10V, 1-5 etc. 24VDC Excitation O/P |
Temperature:
For Thermocouple and RTD inputs. Deg. C/F Display |
Load/Weight:
Loadcell Input, 4 wire |
|
 |
| · |
The
Intuitive Junior range is another version of our Intuitive. |
| · |
As
standard, you get 2 changeover alarm relay outputs. A 5-digit
display gives plenty of scaling flexibility and the power
supplies are wide range switch-mode types. |
| · |
The
front panels are sealed to IP65 and all connections are made
via detachable screw terminals.
<<
BACK TO ELECTRONICS
|
|
| Specifications: |
| Accuracy |
0.1% |
| Excitation |
24V
30mA |
| Tempco |
100ppm/C |
| Resolution |
1:30K |
| Filtering |
Selectable
from 0 to 5 seconds |
| Count
by |
Last
digit may be set to count by 1, 2, 5, 10, 20, or 50 |
| Alarms |
2
SPCO relays 5A 250VAC rated. Adjustable hysteresis. Set
HI or LO |
| Power |
95-265
VAC standard, 11-30 VDC optional. Consumption 5 VA typ. |
| Dimensions |
1/8
DIN bezel. 125mm deep. Weight 300 grammes typ. Cutout 45
x 92mm |
| Temperature |
0-60
degrees operating, -20 to +70 storage. 0-95% RH non
condensing |
| Sealing |
IP65
at front panel |
|
|
|