Mass Technologies, Inc.

P.O. Box 173187

Arlington, TX 76003-3187

 

DM 3600
Home Up

 

 

Universal Inputs
Flow Totalizer Functions
6 Digit Display
Relay & Analog Outputs
RS485 Serial MODBUS Comms
NEMA 4 Front Panel Sealing
Batch Control Function
TFML + OPC Compliant

INTELLIGENT DIGITAL INDICATORS, with TFML
DM3600 Series

INTRODUCTION
The DM3600 is an intelligent digital panel meter that can accept inputs from a wide variety of sensors. The DM3600 is available in two models.  The DM3600U is a universal input panel indicator and the DM3600A is a universal input panel indicator with totalizer functions.  Alarm relays and 4 to 20 mA outputs can be added by means of plug in "Pods".

The use of TFML gives the user the ability to customize the DM3600 to his specific requirements.  Many standard programs are available from our website.  Custom programs can be written quickly and inexpensively.

All functions are programmable from the front panel keys or via the optional RS485 serial port using our M-Config software.  The program is easy to use and intuitive having pull-down menus and dialog boxes.

The DM3600A totalizer function enables non-volatile storage of the integrated total to be maintained within the unit, even after loss of power.  Output options (4 to 20 mA and Alarm Relays) can be selected to operate on either Process Variable Rate or Total.

Applications using the DM3600A as a totalizer.

UNIVERSAL INPUT TYPES

.Minimum Span .Any span within the range can be selected,
 but the recommended span is > 10% of range
.Sensor .Range
.mA .4 to 20, ±0 to 20, ±0 to 10 Linear,
.Square root, X3/2, X5/2, Custom
.RTD .Pt100, Ni120, Cu10
.T / C .Types K, J, T, R, S, B, N, L, E, Custom
.mv .±100 mv
.Volts .±10 V, ±5 V, ±1 to 5 V, ±1 V,
 Linear, X1/2, X3/2, X5/2, Custom

 

.Current Input
.Basic accuracy .0.05% FS ± 0.05% of reading
.Thermal drift: .100 ppm/°F
.Input impedance: .20 ohms
.Linearity: .Linear, X1/2, X3/2, X5/2, Custom 1
.A 19 V @ 25mA power supply is available to power the current loop
...1 Custom can be up to 60 co-ordinate pairs or 
......up to 7 segments of 15th order polynomial

 

.RTD (Pt100) .2 or 3 wire
.Sensor Range .-328 to +1560 °F (18-390 ohms)
.Linearization .BS-EN60751 / JISC 1604 / Custom 1
.Basic Measurement Accuracy .0.2 °F  ±0.05% Reading 2
.Thermal Drift .Zero = 0.008 ohms/°F
.Span = 200 ppm/°F
.Excitation Current .1 mA
.Lead resistance effect .0.004 °F/ohm
.Maximum lead resistance .50 ohms/leg
...1 Custom can be up to 60 co-ordinate pairs or 
......up to 7 segments of 15th order polynomial
...2 Full accuracy for any span > 10% of range

 

.THERMOCOUPLE
.Thermocouple Type Measuring Range
.TC Type K -328 to 2498 °F
.TC Type J -328 to 2192 °F
.TC Type T -346 to 752 °F
.TC Type R 3 -14 to 3200 °F
.TC Type B 4 32 to 3092 °F
.TC Type S 3 -14 to 3200 °F
.TC Type E -328 to 1832 °F
.TC Type L -148 to 1112 °F
.TC Type N -292 to 2392 °F
.Custom -199999 to 999999
.Accuracy .±0.04% Full Range Input ±0.04% Reading
.or 1.0 °F, whichever is greater 2
.Linearization .BS 4937 / EC 584-3 / Custom 1
.Cold Junction Error .±0.05 °F
.Cold Junction Tracking .0.1 °F/°F
.Cold Junction Range .-4 to +140 °F
.Thermal Drift .Zero = 8 µV/°F
.Span = 100 ppm/°F
...1 Custom can be up to 60 co-ordinate pairs or 
......up to 7 segments of 15th order polynomial
...2 Full accuracy for any span > 10% of range
...
3 Accuracy true for 932°F to 3200°F
...4 Accuracy true for 752°F to 3000°F

 

.Voltage Input
.Basic accuracy .0.04% FS ± 0.04% of reading 2
.Thermal Drift .50 ppm/°F
.Input Impedance .1 M ohm
.Linearity  Linear, X1/2, X3/2, X5/2, Custom 1
.Range .±100 mV, ±1 V, ±5 V, ±10 V, ±1 to 5 V
...1 Custom can be up to 60 co-ordinate pairs or 
......up to 7 segments of 15th order polynomial
...2 Full accuracy for any span > 10% of range

 

.Remote Digitals Output
.Two isolated digital inputs are available to reset latched alarms, reset peak,
.and valley memories, reset total or for customized use with TFML

 

OUTPUT OPTIONS
Plug and Play Option Pods
Simple plug in pre-calibrated units, no dismantling or calibration

..Pod-3000/02  Dual relay Alarm
..
Two independent line rated relay outputs
.Contacts .2 x Changeover relays common wiper
.Ratings .AC .DC
.Maximum Load .5A @ 250 V .5A @ 30V
.Maximum Power .1250 Watts .150 Watts
.Maximum Switching .253 Volts .125 Volts
.Electrical Life .100,000 operations at rated load
.Mechanical Life .50 million operations
.Termination
Standard... .5 way tension clamp connector
Optional... .Screw terminals

 

..Pod-3000/03  Isolated re-transmission
.Ranges .0 to 10 ma (Active or Passive)
.0 to 20 ma (Active or Passive)
.4 to 20 ma (Active or Passive)
.Minimum current output .0 ma
.Maximum current output .23 ma
.Accuracy .0.07% full scale
.Resolution .1 part in 30,000
.Maximum Output load
Active... .1 k ohm
Passive... .[(V supply - 2) / 20] k ohms
.Maximum External Supply Voltage .30 V (Passive mode)
.Voltage effect .0.2 µA/V
.Ripple current .< 3 µA
.Isolation .500 VAC
.Stability .2 µA/°F
.Termination
Standard... .5 way tension clamp connector
Optional... .Screw terminals

.Voltage Outputs

.Voltage Outputs may be obtained by
 connecting an external resistor and
 selecting the appropriate current range,
 as shown in table below.
.Resistance .Current .Output
.1 Kohms .0 to 10 ma .0 to 10 VDC
.250 ohms .0 to 20 ma .0 to 10 VDC
.250 ohms .4 to 20 ma .1 to 5 VDC

GENERAL SPECIFICATIONS (@ 20°C)

.Filter (Secs.) .Off, 2 seconds, 10 seconds or Adaptive
.Power Supply .S1 = 90 to 253 VAC 50/60 Hz
.S2 = 20 to 35 VDC
.Power Consumption .10 VA max. (worst case)
.Isolation (Tested to) .I/O Ports    500 V
.
Supply to I/O    3750 V

ENVIRONMENTAL

.Sealing to PANEL .NEMA 4, IP65
.Ambient operating range .-22 to +140 °F
.Ambient storage temperature .-58 to +185 °F
.Ambient humidity range .10 to 90% RH non condensing
.EMC: Emissions & Immunity .BS EN61326
.Safety .BS EN61010-1

SET UP
Configuration can be set up either from the integral front panel keys or via the serial Modbus communications interface. The front panel keys and display give access to a user menu. The menu can be set to 'Short' whereby only the most common menu items are presented or 'Full' where all editable fields are presented. The following table shows the menu fields:

..Feature ..Short Menu ..Full Menu
.DM3600U
.Universal Indicator
.Sensor type
.Range
.Linearity
.User Linearization
.Decimal Point
.Engineering Lo
.Engineering Hi
.Autoscale
.Units
.Burnout
.Filter
.DM3600A
.Universal Indicator
.with Flow Totalization
.Sensor type
.Range
.Linearity
.User Linearization
.Decimal Point
.Display Rate / Total
.Engineering Lo
.Engineering Hi
.Autoscale
.Units
.Burnout
.Filter
.
Total Reset
.Divider
.Factor
.Time Base
.Dual Alarm Relays 6
.Pod-3000/02
.Setpoint
.Alarm Action
.Hysterisis
.Delay
.Latch
.Invert - NO/NC
.Lo:Hi
.Isolated Current
.Re-Transmission 5
.Pod-3000/03
.Retransmission
.Type
.Span
.Preset Level
.......5 "U" Version only
.  ....6 Can be applied to either Rate or Total for "A" Version

Other Software Features
Start up alarm delay
Peak and Valley Memories 5
Password Protection
Set Baud Rate
Set Device Address
Set 2 or 4 wire Comms

The following functions are available via the front panel while the unit is in operation:
Clear:  latched alarms, Total, peak / valley
Edit Setpoint Shortcut
Show peak reading 5
Show valley reading 5
Show Secondary Variable 7
Show Electrical Value 7
Show upper 6 digits of total 7

.....Notes:
.......5 "U" Version only
.  ....6 Can be applied to either Rate or Total for "A" Version
.......7 "A" Version only

CONNECTIONS

.Input .5 way tension clamp connector (2 Part)
.Comms + Digitals .8 way RJ45 connector
.(Supplied with matching plug and 1 M Cable)

COMMUNICATIONS
RS 485 Modbus Communications
The DM3600 is available with RS485 serial communications using MODBUD RTU protocol, and is supplied with OPC Client Server software, compatible with the vast majority of software platforms used in the process control industry.

.Physical Layer .4 wire or 2 wire half duplex RS485
.Baud Rate software selectable .19,200 or 9,600
.Protocol .Modbus RTU format
.Isolation .500 VAC
.Maximum Fan out .32 units (can be increased with repeaters)
.Termination Standard .RS485

M-CONFIG
With the RS485 Modbus serial communications option fitted, remote programming and interrogation can be performed from a PC.  To facilitate this, Status Instruments has written a comprehensive, easy to use, configuration software program called M-Config, which is available free of charge from our web site.  This program is also used with our MEDACS series signal conditioners.

OPC Server
Managed by the OPC Foundation, OPC (Object linking and embedding for Process Control) is an industry standard created with collaboration of a number of leading worldwide automation and hardware / software suppliers working in cooperation with Microsoft.

The goal of the standard is 'Plug-and-Play'. By using the standard OPC client-server model, any OPC-compliant device will quickly, easily and seamlessly connect to another and immediately work without the need for lengthy installation procedures. The user can then concentrate more on the chosen client software package (e.g. DCS, SCADA, HMI Plant Scheduling) rather than the problems of system integration.

OPC Client Server software is optionally available.  This allows the DM3600 to be quickly, easily and seamlessly integrated into any client software package that has an OPC output.

DOWNLOADS

DM3600 Literature


ORDER CODE

DM3600 / Input / Communications / Power Option

.DM3600 Basic Model Number
.Input Options .U = Universal Input
.A = Universal Input + Totalizer
.Communications Options .00 = No Comms
.01 = Modbus Serial RS485 Comms + TFML Upgrade
.Power Options .S1 = 90 to 253 VAC 50/60 Hz
.S2 = 20 to 35 VDC

OPTIONS

.OPT-3600-02/01 .DIN rail mounted Break-out board to connect RJ45 
.to Screw Terminals
.OPT-3600-02/02 .DIN rail mounted Break-out board to connect RJ45 
.9-Way D-Type
.Pod-3000/02 .Dual Relay Output (2 per unit maximum)
.Pod-3000/03 .Isolated 4 to 20 mA re-transmission (1 per unit maximum)
.RMK3000 .DIN Rail Mounting Kit
.M-Config .Configuration tool. This package is also available
.as a free download from our website.
.M-OPC .Full functionality OPC server.
 

 

Home ] Up ]